 |
|
Home |
Why Solar Thermal |
Products |
System Designs |
Incentives |
News |
Contact Us |
Dealers |
Become a Dealer
|
| |
|
Solar Water Works founder, Randy Reu, was interviewed for and quoted in the recent
Wall Street Journal Article entitled:
"Let the Sunshine In - Sick of high energy bills, our columnist investigates solar options".
Read the full story on their site at:
$$$
See how much you can save on your annual energy costs by converting to
Solar Water Heating!
|
|
|
| |
SOLAR WATER WORKS PRODUCTS
 |
COLLECTORS
Efficient collectors are the most important component of any solar system.
Even a small increase in efficiency will save you thousands of dollars long term, so make sure
you have the best. Apricus collectors are the ideal way to convert everyday sunlight into heat for
hot water or winter space heating. Most homes with good sun exposure will require one 30 tube
collector but larger space heating projects can take advantage of multiple collectors in series
|
10 Tube Collector

|
Each AP 10 Kit includes:
- 10 Apricus Evacuated Tubes
- Powder coated aluminum manifold
- Standard Flush Mount Frame
- Roof Attachment pads
- Thermal Paste (for heat conduction, applied to HP prior to insertion)
- Solar tube rubber caps
- Tube Attachment Clips
- 2 x 22C to 1/2” M DR brass compression fittings
- 20 Nylon cable ties (10 x 3x100m, 10 x 4x200mm)
- Component packing list & frame assembly diagrams
|
20 Tube Collector

|
Each AP 20 Kit includes:
- 20 Apricus Evacuated Tubes
- Powder coated aluminum manifold
- Standard Flush Mount Frame
- Roof Attachment pads
- Thermal Paste (for heat conduction, applied to HP prior to insertion)
- Solar tube rubber caps
- Tube Attachment Clips
- 2 x 22C to 1/2” M DR brass compression fittings
- 20 Nylon cable ties (10 x 3x100m, 10 x 4x200mm)
- Component packing list & frame assembly diagrams
|
30 Tube Collector

|
Each AP 30 Kit includes:
- 30 Apricus Evacuated Tubes
- Powder coated aluminum manifold
- Standard Flush Mount Frame
- Roof Attachment pads
- Thermal Paste (for heat conduction, applied to HP prior to insertion)
- Solar tube rubber caps
- Tube Attachment Clips
- 2 x 22C to 1/2” M DR brass compression fittings
- 20 Nylon cable ties (10 x 3x100m, 10 x 4x200mm)
- Component packing list & frame assembly diagrams
|
Standard Frame
|
Every collector comes complete with a standard mounting frame. This frame is used to install the collector
flush on an angled roof. If your roof has a low pitch several additional stainless steel frames
are available for installation.
|
Low Angle Frame
|
If your roof is less than your latitude (i.e. 45 degrees) then you may wish to use the low angle mount.
This will give you a range of 9-22 degrees in addition to the angle of the roof. Simple to put together and easy to install.
|
Mid Angle Frame
|
For roofs less than your latitude (i.e. 45 degrees) and closer to flat than vertical you will need to
use the Mid Angle Mount. This will give you a range of 21-28 degrees in addition to the angle of the roof.
Simple to put together and easy to install.
|
High Angle Frame
|
Use this mount on flat roofs to reach up to 50 degrees.
|
Flat Roof Frame
|
For commercial flat roof applications use the High Angle Mount to reach up to 50 degrees.
|
Vertical Wall Frame
|
You may choose to mount your collectors to the side of a wall with a Mid Angle or High Angle Mount.
|
 |
SYSTEMS
We are currently working on the pricing and packaging of standard residential
systems. Please stop back again soon. |
 |
Kits & Components
Check back soon for additional system installation accessories. |
Solar Conversion Valve
The innovative “Solar Conversion Valve” converts almost any ordinary tank into a fully functional solar ready storage tank.
Auto Air Vent
The Apricus Auto Air Vent allows for air to leave the solar loop without costly modifications to the system.
Sentinel-Pro Controller
The Apricus Sentinel-Pro controller is one of the most sophisticated Delta T controllers on the market.
|

|
Solar Conversion Valve
The Apricus heat dissipator (HD) is specifically designed for use with Apricus solar collector installations
that are sized for optimal winter, spring and autumn output. The HD can dissipate the excessive heat produced
during summer periods, or periods of non-use. This protects systems from overheating and/or excessive hot water dumping.
Key Features
- >1.3kW heat dissipation capacity*
- Suitable for fresh water or glycol/water systems.
- Anodized aluminiun fins and outer casing for excellent corrosion resistance
- Silver brazed copper piping with 1/2"M BSP inlet and outlet.
- Easy mounting on exterior wall or in roof space.
- Able to be connected in series for greater heat dissipation capacity.
- Minimal pressure drop.
- May be used as a simple hydronic space heating panel.
- Neat, attractive design.
* Based on 80°C / 176°F water temp, 40°C / 104°F ambient, no forced air flow.
Installation Overview
The HD is installed on the return line from the solar collector(s). When the temperature in the storage tank exceeds
the pre-set limit (~80°C / 176°F), the controller switches a solenoid which directs the solar return flow
through the HD before returning it back into the standard flow line. Alternatively a thermostatic mixing valve/tempering
valve set to a suitable temperature can be used, providing mechanic, automatic regulation of flow through the heat
dissipator.
As the hot water passes through the HD, heat is dissipated via the aluminium fins to surrounding air, the
vertical fin arrangement promoting a passsive air current.
One HD-25 unit can dissipate 100% of the heat produced by an AP-30 collector in full sun,
during very high ambient temperatures.
The copper pipe to and from the collector should be heavily insulated, as should the lengths of pipe to
and from the HD. The solenoid valve prevents flow of collector return water through the HD during normal
temperature operation, thus preventing unnecessary heat loss.
|
|
Pump Stations
The Solar Pump Station
Pumps, Heat Exchanger, and Digital Controller All-in-One
Neatly packaged and designed to simplify any solar hot water installation.
The Pump Station forms the basis for a Closed Loop system. It circulates a Water/Glycol mixture to the collectors
and back to a heat exchanger, where it transfers the heat to the potable (drinkable) water loop for storage and use.
In a closed loop system, there are two “loops”, or piping circuits. The “solar loop” travels to the solar
collector and back, and the “potable loop” draws water from the storage tank and returns it warmer.
The two loops are separate and do not mix, but both connect to the Pump Station where the heat is transferred
from the solar to the potable loop.
For the solar loop, the unit contains the heat exchanger, a circulator pump, pressure/temperature gauge,
fill/drain valve, pressure relief valve, and check valve.
For the potable loop, the unit contains the heat exchanger and a circulator pump.
Animated Graphic
(From Purist Energy)
Solar Pump Station SPS-2-AC
This is a Dual Pump; AC powered unit that plugs in to a standard outlet running on a mere 30 watts.
This unit contains workings for both the solar loop and the potable loop. These loops consist of;
two circulator pumps, heat exchanger, fill valve, drain valve, pressure relief valve,
check valve and a pressure/temperature gauge.
In addition this unit contains a controller, automatically turning the pumps on when the collector starts
to heat the water. The controller can also be used to power additional motors, control other heat loops
or eliminate excess heat from the system if necessary.
All in one nice neat easy to install package!
|

SPS-2-AC Specifications
|
Solar Pump Station SPS-2-DC
This is a Dual Pump, DC (PV) powered Residential Solar Hot Water Appliance.
This unit contains workings for both the solar loop and the potable loop.
These loops consist of; two circulator pumps, heat exchanger, fill valve, drain valve,pressure relief valve,
check valve and a pressure/temperature gauge.
It is designed for use with a Photo Voltaic Panel. The (PV) panel works in sink with the collector.
When the sun is shining the solar thermal collector and the (PV) panel will both be working,
when the sun sets it automatically goes off.
All in one nice neat easy to install package!
|

SPS-2-DC Specifications |
Solar Pump Station SPC-2-AC
This is a Dual Pump, AC powered Commercial Solar Thermal System.
Prototypes in progress!
|
SPC-2-AC Specifications |
|
|
|